Daewoo DS-360 Bedienungsanleitung Seite 15

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 39
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 14
(7) Speed command voltage [symbol U, 0 ±10V]
- Display external speed command voltage or speed limit command voltage.
U-10.00 U0U10.00
CW CCW
(8) Torque command voltage [symbol t, 0 ±10V]
- Display torque command voltage.
t-10.00 t0t10.00
CW CCW
(9) Effective load factor [symbol L, -300 300%]
- Display continuous effective load torque.
- Display 100 percent at a rated torque.
L 100
(10) Max load factor [symbol H, -300 300%]
- Display peak torque under Acceleration/Deceleration,
it is able to alter to the largest value.
- Display 100 percent at a rated torque.
- If the set button pressed, Reset in 0 ”.
H 100
6.5. ALARM HISTORY DISPLAY DESCRIPTION
NAME DISPLAY CONTENTS
Alarm History
AL0-UU
AL1-UU
AL9-UU
- Display alarm history to 9-rotates recently.
- Reset alarm history by pressing SET key.
Seitenansicht 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 38 39

Kommentare zu diesen Handbüchern