8. Accessory input
The Auxiliary Terminal N accepts input signals from load sharing units, auto synchronizers, and
other governor system accessories, accessories are directly connected to this terminal It is
recommended that this connection from accessories be shielded as it is a sensitive input terminal.
If the auto synchronizer is used alone, not in conjunction with a load sharing module, a 3M ohm
resistor should be connected between Terminals N and P This is required to match the voltage
levels between the speed control unit and the synchronizer.
When an accessory is connected to Terminal N, the speed will decrease and the speed
adjustment must be reset.
When operating in the upper end of the control unit frequency range, a jumper wire or frequency
trim control may be required between Terminals G and J. This increases the frequency range of
the speed control to over 7000 Hz.
9. Accessory Supply
The +10 volt regulated supply, Terminal P, can be utilized to provide power to governor system
accessories. Up to 20mA of current can be drawn from this supply. Ground reference is Terminal
G. A short circuit on this terminal can damage the speed control unit.
10. Wide Range Remote Variable Speed Operation
A single remote speed adjustment potentiometer can be used to adjust the engine speed
continuously over a specific speed range. Select the desired speed range and the corresponding
potentiometer value. (Refer to “Speed Range Potentiometer Value”) If the exact range cannot be
found, select the next higher range potentiometer. An additional fixed resistor may be placed
across the potentiometer to obtain the exact desired range. Connect the speed range
potentiometer as shown in the next diagram.
<Speed Range Potentiometer Value>
* Select Proper Potentiometer Value
Caution :
To maintain engine stability at the
minimum speed setting, a small amount
of droop can be added using the
DROOP adjustment. At the maximum speed setting the governor performance will be near
isochronous, regardless of the droop adjustment setting.
Contact the factory for assistance if difficulty is experienced in obtaining the desired variable
speed governing performance.
- 133 -
Speed Range Potentiometer Value
900 Hz. 1K
2,400 Hz. 5K
3,000 Hz. 10K
3,500 Hz. 25K
3,700 Hz. 50K
GJ KL
CW
EA6M4005
Seitenansicht 135