Gently remove the compressor cover (8),
and fitted, remove the O ring seal (41).
Caution : The compressor wheel blades
can be easily damaged when
the compressor housing is
removed.
•
Loosen and remove the 6 bolts (57) and
clamp plates (88).
Caution : The turbine blades can be
easily damaged when the
turbine housing is removed.
•
Locate the Center Housing Rotating
Assembly (CHRA) onto a 19mm socket
clamped in the jaws of a vice or a suitable
fixture.
Caution : Always make sure the turbine
wheel shaft and the
compressor wheel have
alignment marks before
disassembly of the CHRA.