Inspection points on the voltage regulator
<Resistance value between voltage regulator’s terminals>
(2) Precautions in use
Pay attention to dropping the battery voltage capacity when they are left for long time even
without use.
In cold winter season, for the starting may not be done well sometime, do not try it to be
continuous immediately but try to start again after waiting about 30 seconds.
Prior to operating the gauge panel, make sure of the polarity of battery once again (In
general, red side means “+” and black one is “-”.)
Disassembling the gauge panel may be accompanied with a risk of electrical shock, First
detach the cable from the connector at the rear side of the gauge panel without fail, then
disassemble it.
If metallic foil is used for safety connector instead of the cut-off fuse, excessive current that
can make serious damage might flow into the electric parts of the engine. (Never do this!) If
cutting off of fuse is occurred, solve the problem, then replace it with a new fuse.
Since battery has a danger of explosion by a heat, it must not be installed at the place where
there generates a lot of heat.
When engine is in stop, always pull out the key. Then a hazard of fire or wound due to wrong
operation may not happen.
In case of scrapping the batteries, observe the followings.
NOTE : Do not throw it in the fire to scrap. It should not be thrown away into the places where
are liable to cause the environmental pollution such as stream, river and mountain.
Pack them as far as possible and dispose it as rubbish that is unable to use again.
DAEWOO will not be responsible to the problems that might be raised by the disassembling
and structural change of this product without consultation.
- 48 -
Resistance Value
(KΩ)
+-
L E about 2
R E about 53
F E about 50
L F about 50
R L about 50
R F about 168
Terminal
Resistance Value
(KΩ)
+-
ER
LR
FR
Terminal
Seitenansicht 50